CEMR Online Help
Client Self Test provides Wholesale customers with the ability to perform testing on their DS1 circuits. A CEMR customer with valid CEMR credentials is able to log in and run a Full Test as if CenturyLink were conducting the test via Test Expert.
Note: A customer who runs a Full Test could experience circuit down time. A pop-up message will read: “Warning this is an intrusive test. The circuit will be taken out of service for the duration of the test.”
The test provides all of the information CenturyLink is able to collect via Test Expert.
Test Expert Results |
Summary Code |
Text Response |
No test access available |
NTA |
No test access available – Please open a ticket. |
DS1 PM’s clean |
CLN |
DS1 PM’s Clean |
Test OK |
TOK |
No trouble found on the circuit |
Errors in CenturyLink Network (line) |
ERL |
Errors in the CenturyLink network – Please open a ticket |
Errors Not Isolated (path) |
ERP |
Errors detected, not isolated – Please review before opening a ticket |
HDSL errors detected |
TQF |
Trouble Found in CenturyLink network field – Please open a ticket. |
Trouble to the office repeater |
TQO |
Trouble Found in CenturyLink network office - Please open a ticket |
Inconclusive results |
INC |
Unspecified failure took place – Please open a ticket |
Errors to NIU or Field devices |
TQF |
Trouble Found in CenturyLink network – NIU or Repeaters – Please open a ticket |
CPE |
CPE |
Clean to NIU, taking errors to the CSU – Please contact your end user and isolate trouble further |
Alarm Red |
ALR |
RED ALARM detected. No further trouble found. |
Alarm Yellow |
ALY |
YELLOW ALARM detected. No further trouble found. |
OOS, CenturyLink network TOK |
QOK |